Seacoast

Want to stay connected with Seacoast? Sign up for our emails today.

<meta name="google-site-verification" content="3TGVx_bTNjrNhgn43zWfOR7K8hz1G7bglK6OjcYohws" />

Home
0
MY QUOTE{0} items in cart

2XSOW30

2XSOW12

Spec #:M24640/16-05UO

MFR #:M24640/16-05UO

GCG #:2XSOW30

Spec #:M24640/16-05UO

MFR #:M24640/16-05UO

GCG #:2XSOW30

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-05UO (2XSOW30) is a 600V light weight, non-watertight cable with non-flexing service. M24640/16-05UO has 60 18 AWG conductors with a minimum diameter of 1.18 and a maximum diameter of 1.27 inches. 2XSOW30 has a bend radius of 15.5 inches, and is Individually & Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-05UO (2XSOW30) is a 600V light weight, non-watertight cable with non-flexing service. M24640/16-05UO has 60 18 AWG conductors with a minimum diameter of 1.18 and a maximum diameter of 1.27 inches. 2XSOW30 has a bend radius of 15.5 inches, and is Individually & Overall Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count60
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)1.27
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually & Overall Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)1.18
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)15.5
Weight per Foot1.442