Seacoast

Want to stay connected with Seacoast? Sign up for our emails today.

<meta name="google-site-verification" content="3TGVx_bTNjrNhgn43zWfOR7K8hz1G7bglK6OjcYohws" />

Home
0
MY QUOTE{0} items in cart

2XSW3

2XSW1

Spec #:M24640/16-02UN

MFR #:M24640/16-02UN

GCG #:2XSW3

Spec #:M24640/16-02UN

MFR #:M24640/16-02UN

GCG #:2XSW3

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-02UN (2XSW3) is a 600V light weight, watertight cable with non-flexing service. M24640/16-02UN has 6 18 AWG conductors with a minimum diameter of 0.436 and a maximum diameter of 0.47 inches. 2XSW3 has a bend radius of 4 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.
Requires Quote

Min Qty:1

  |  

Qty Increment:1

Seacoast USA's M24640/16-02UN (2XSW3) is a 600V light weight, watertight cable with non-flexing service. M24640/16-02UN has 6 18 AWG conductors with a minimum diameter of 0.436 and a maximum diameter of 0.47 inches. 2XSW3 has a bend radius of 4 inches, and is Individually Shielded with Cross-Linked Polyalkene insulation material and a Cross-Linked Polyvinylidene Flouride (PVDF) external jacket, operating from -20°C to +105°C. Multipair, 7 strand tinned copper conductor, extruded irradiation cross-linked Polyalkene insulation with irradiated cross-linked Polyvinylidene Flouride (PVDF) insulation jacket (conductors per SAE-AS81044). Two conductors twisted to form a pair, tinned copper braid shielded, plus a tape shielded isolation. The required number of pairs cabled consecutively, optional binder tape, cross-linked Polyolefin jacket, surface marking. Standard Identification Code by Method 2.

Attributes

Environmental Properties
Temperature Rating (Range)-20°C to +105°C
General Information
ManufacturerSeacoast
Design & Construction
Conductor MaterialTin-Coated Copper
Conductor Count6
Jacket MaterialCross-Linked Polyvinylidene Flouride (PVDF)
Cable Diameter Max (in)0.47
Solid/StrandedStranded
Stranding7
Shielded/UnshieldedIndividually Shielded
Shield TypeTape & Tin-Coated Copper Braid
Cable Diameter Min (in)0.436
Electrical Properties
Insulation MaterialCross-Linked Polyalkene
Voltage Rating600V
Physical Properties
Bend Radius (in)4
Weight per Foot0.175